| PV String Input Data | |||||||
| Max. PV Input Power (W) | 210-460 | 210-560 | 210-630 | 210-700 | 210-630 | 210-770 | 210-770 |
| (4 Pieces) | (4 Pieces) | (4 Pieces) | (4 Pieces) | (4 Pieces) | (4 Pieces) | (4 Pieces) | |
| Max. PV Input Voltage (V) | 60 | ||||||
| Start-up Voltage (V) | 20 | ||||||
| MPPT Voltage Range (V) | 25-55 | ||||||
| Rated PV Input Voltage (V) | 42.5 | ||||||
| Max. Operating PV Input Current (A) | 15+15+15+15 | 18+18+18+18 | |||||
| Max. Input Short Circuit Current (A) | 22.5+22.5+22.5+22.5 | 27+27+27+27 | |||||
| No. of MPP Trackers/No. of Strings per MPP Tracker | 4/1 | ||||||
| AC Output Side | |||||||
| Rated AC Output Active Power (W) | 1300 | 1600 | 1800 | 2000 | 1800 | 2000 | 2200 |
| Max. AC Output Apparent Power (VA) | 1300 | 1600 | 1800 | 2000 | 1800 | 2000 | 2200 |
| Rated AC Output Current (A) | 6/5.7 | 7.3/7 | 8.2/7.9 | 9.1/8.7 | 8.2/7.9 | 9.1/8.7 | 10/9.6 |
| Max. AC Output Current (A) | 6/5.7 | 7.3/7 | 8.2/7.9 | 9.1/8.7 | 8.2/7.9 | 9.1/8.7 | 10/9.6 |
| Rated Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | ||||||
| Grid Connection Form | L/N/PE | ||||||
| Rated Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||||
| Max. Unit per Branch | 5 | 4 | 3 | 3 | 3 | 3 | 3 |
| Power Factor Adjustment Range | 0.9 leading to 0.9 lagging | ||||||
| Total Current Harmonic Distortion THDi | <3% | ||||||
| DC Injection Current | <0.5%ln | ||||||
| Efficiency | |||||||
| Max. Efficiency | 96.50% | ||||||
| Euro Efficiency | 96.00% | ||||||
| MPPT Efficiency | >99% | ||||||
| Equipment Protection | |||||||
| DC Polarity Reverse Connection Protection | Yes | ||||||
| AC Output Overcurrent Protection | Yes | ||||||
| AC Output Overvoltage Protection | Yes | ||||||
| AC Output Short Circuit Protection | Yes | ||||||
| Thermal Protection | Yes | ||||||
| DC Terminal Insulation Impedance Monitoring | Yes | ||||||
| Power Network Monitoring | Yes | ||||||
| Island Protection Monitoring | Yes | ||||||
| Earth Fault Detection | Yes | ||||||
| Overvoltage Load Drop Protection | Yes | ||||||
| Interface | |||||||
| Communication Interface | WiFi | ||||||
| General Data | |||||||
| Operating Temperature Range | -40°C to +65°C >45°CDerating | ||||||
| Permissible Ambient Humidity | 0-100% | ||||||
| Permissible Altitude (m) | 2000m | ||||||
| Noise (dB) | ≤25 | ||||||
| Ingress Protection(IP) Rating | IP 67 | ||||||
| Inverter Topology | Isolated | ||||||
| Over Voltage Category | OVC II(DC), OVC III(AC) | ||||||
| Cabinet Size (WxHxD mm) | 311*250.5*36.5 (Excluding Connectors and Brackets) | 358*255.5*36.5(Excluding Connectors and Brackets) | |||||
| Weight (kg) | 5.1 | 5.2 | |||||
| Warranty | 10 Years | ||||||
| Type of Cooling | Natural Cooling | ||||||
| Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25, G99, VDE-AR-N 4105 | ||||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||||
Certification